Citations
All
Search in:AllTitleAbstractAuthor name
Publications
(4K+)
Patents
Grants
Pathways
Clinical trials
The language you are using is not recognised as English. To correctly search in your language please select Search and translation language
Publication
Journal: American Journal of Infection Control
April/25/2020
Publication
Journal: Environmental Science & Technology
December/16/2009
Abstract
Two challenges for improving the performance of air cathode, single-chamber microbial fuel cells (MFCs) include increasing Coulombic efficiency (CE) and decreasing internal resistance. Nonbiodegradable glass fiber separators between the two electrodes were shown to increase power and CE, compared to cloth separators (J-cloth) that were degraded over time. MFC tests were conducted using glass fiber mats with thicknesses of 1.0 mm (GF1) or 0.4 mm (GF0.4), a cation exchange membrane (CEM), and a J-cloth (JC), using reactors with different configurations. Higher power densities were obtained with either GF1 (46 +/- 4 W/m(3)) or JC (46 +/- 1 W/m(3)) in MFCs with a 2 cm electrode spacing, when the separator was placed against the cathode (S-configuration), rather than MFCs with GF0.4 (36 +/- 1 W/m(3)) or CEM (14 +/- 1 W/m(3)). Power was increased to 70 +/- 2 W/m(3) by placing the electrodes on either side of the GF1 separator (single separator electrode assembly, SSEA) and further to 150 +/- 6 W/m(3) using two sets of electrodes spaced 2 cm apart (double separator electrode assembly, DSEA). Reducing the DSEA electrode spacing to 0.3 cm increased power to 696 +/- 26 W/m(3) as a result of a decrease in the ohmic resistance from 5.9 to 2.2 Omega. The main advantages of a GF1 separator compared to JC were an improvement in the CE from 40% to 81% (S-configuration), compared to only 20-40% for JC under similar conditions, and the fact that GF1 was not biodegradable. The high CE for the GF1 separator was attributed to a low oxygen mass transfer coefficient (k(O) = 5.0 x 10(-5) cm/s). The GF1 and JC materials differed in the amount of biomass that accumulated on the separator and its biodegradability, which affected long-term power production and oxygen transport. These results show that materials and mass transfer properties of separators are important factors for improving power densities, CE, and long-term performance of MFCs.
Publication
Journal: British Medical Journal
April/8/2020
Publication
Journal: Parasites and Vectors
August/28/2014
Abstract
BACKGROUND
Entomopathogenic fungi could be useful tools for reducing populations of the dengue mosquito Aedes aegypti. Here the efficiency of fungus (Metarhizium anisopliae) impregnated cloths (with and without imidacloprid [IMI]) was evaluated against adult A. aegypti in simulated human dwellings. Behaviour of mosquitoes in the presence of black cloths was also investigated.
RESULTS
When mosquitoes were released into the test rooms, the lowest survival rates (38%) were seen when five black cloths impregnated with conidia of ESALQ 818 + 10 ppm IMI were fixed under tables and chairs. This result was significantly lower than the survival rate recorded when cloths were impregnated with ESALQ 818 alone (44%) or ESALQ 818 + 0.1 ppm IMI (43%). Blood fed A. aegypti had lower landing frequencies on black cloths than sucrose fed insects during the first 24 h following feeding, which may have been due to reduced flight activity. Few mosquitoes (4-5%) were observed to land on the cloths during the hours of darkness. The landing pattern of sucrose-fed mosquitoes on non-treated and fungus-treated cloths was similar.
CONCLUSIONS
The synergism between M. anisopliae and IMI significantly reduced Aedes survival in simulated field conditions. The use of fungus impregnated cloths is a promising point source application method for the control of adult A. aegypti.
Publication
Journal: Annals of Surgery
March/31/2014
Abstract
OBJECTIVE
Experiments were performed to determine the risk of bacterial contamination associated with changing outer gloves and using disposable spunlace paper versus reusable cloth gowns.
BACKGROUND
Despite decades of research, there remains a lack of consensus regarding certain aspects of optimal aseptic technique including outer glove exchange while double-gloving and surgical gown type selection.
METHODS
In an initial glove study, 102 surgical team members were randomized to exchange or retain outer gloves 1 hour into clean orthopedic procedures; cultures were obtained 15 minutes later from the palm of the surgeon's dominant gloved hand and from the surgical gown sleeve. Surgical gown type selection was recorded. A laboratory strike-through study investigating bacterial transmission through cloth and paper gowns was performed with coagulase-negative staphylococci. In a follow-up glove study, 251 surgical team members, all wearing paper gowns, were randomized as in the first glove study.
RESULTS
Glove study 1 revealed 4-fold higher levels of baseline bacterial contamination (31% vs 7%) on the sleeve of surgical team members wearing cloth gowns than those using paper gowns [odds ratio (95% confidence interval): 4.64 (1.72-12.53); P = 0.0016]. The bacterial strike-through study revealed that 26 of 27 cloth gowns allowed bacterial transmission through the material compared with 0 of 27 paper gowns (P < 0.001). In glove study 2, surgeons retaining outer gloves 1 hour into the case had a subsequent positive glove contamination rate of 23% compared with 13% among surgeons exchanging their original outer glove [odds ratio (95% confidence interval): 1.97 (1.02-3.80); P = 0.0419].
CONCLUSIONS
Paper gowns demonstrated less bacterial transmission in the laboratory and lower rates of contamination in the operating room. Disposable paper gowns are recommended for all surgical cases, especially those involving implants, because of the heightened risk of infection. Outer glove exchange just before handling implant materials is also recommended to minimize intraoperative contamination.
Publication
Journal: Journal of Ethnopharmacology
April/20/2020
Abstract
Gardenia jasminoides Ellis is a popular shrub in the Rubiaceae family. The desiccative ripe fruits of this plant (called Zhizi in China) are well known and frequently used not only as an excellent natural colorant, but also as an important traditional medicine for the treatment of different diseases, such as reducing fire except vexed, clearing away heat evil, and cooling blood and eliminating stasis to activate blood circulation. It has also been declared as the first batch of dual-purpose plants used for food and medical functions in China.This review aims to provide a critical and systematic summary of the traditional uses, ethnopharmacology, phytochemistry, pharmacology, toxicity and industrial applications of Gardenia jasminoides Ellis and briefly proposes several suggestions for future application prospects.The related information on Gardenia jasminoides Ellis was obtained from internationally recognized scientific databases through the Internet (PubMed, CNKI, Google Scholar, Baidu Scholar, Web of Science, Medline Plus, ACS, Elsevier and Flora of China) and libraries.Approximately 162 chemical compounds have been isolated and identified from this herb. Among them, iridoid glycosides and yellow pigment are generally considered the main bioactive and characteristic ingredients. Various pharmacological properties, such as a beneficial effect on the nervous, cardiovascular and digestive systems, hepatoprotective activity, antidepressant activity, and anti-inflammatory activity, were also validated in vitro and in vivo. Moreover, geniposide and genipin are the most important iridoid compounds isolated from Gardenia jasminoides Ellis, and genipin is the aglycone of geniposide. As the predominant active ingredient with a distinct pharmacological activity, genipin is also an outstanding biological crosslinking agent. Gardenia yellow pigment has also been widely used as an excellent natural dye-stuff. Hence, Gardenia jasminoides Ellis has been applied to many other fields, including the food industry, textile industry and chemical industry, in addition to its predominant medicinal uses.According to this review, Gardenia jasminoides Ellis is outstanding traditional medical plant used in medicine and food. Pharmacological investigations support the traditional use of this herb and may validate the folk medicinal use of Gardenia jasminoides Ellis to treat different diseases. Iridoid glycosides are potential medicines. Gardenia yellow pigment has been the most important source of a natural colorant for food, cloth and paint for thousands of years. This herb has made great contributions to human survival and development. Moreover, it has also achieved outstanding progress in human life and even in art. Although Gardenia jasminoides Ellis has extremely high and comprehensive utilization values, it is still far from being completely explored. Therefore, the comprehensive development of Gardenia jasminoides Ellis deserves further analysis.
Publication
Journal: Sexual Health
January/29/2007
Abstract
BACKGROUND
Women in sex work stand to benefit if the contraceptive diaphragm alone or combined with a microbicide proves to be an effective barrier method against HIV and sexually transmissible infection (STI). Currently, contraceptive diaphragm users are advised to leave the diaphragm in situ without concomitant use of other intravaginal substances for at least 6 h after intercourse.
METHODS
We conducted in-depth interviews on sexual behaviour including post-coital intravaginal practices with 36 women in sex work and 26 of their clients and held two focus-group discussions, each with 10 women.
RESULTS
The women described adapting several potentially harmful substances, such as cloth and soapy water, for post-coital vaginal use to ensure personal hygiene, disease prevention and client pleasure. Some wanted to clean themselves and remove the diaphragm early, fearing exposure to HIV infection for themselves and their subsequent clients. Clients indicated their desire for 'dry sex', vaginal cleanliness and reduced risk of infection through vaginal cleaning.
CONCLUSIONS
The diaphragm as a female-controlled barrier method for HIV/STI prevention may have limited acceptability among women in sex work if its effectiveness depends on a 6-h post-coital wait before removal, along with avoidance of concomitant use of intravaginal substances. In keeping with the beliefs of the the female sex workers and their needs and practices, alternative intravaginal substances and modes of insertion that will not disrupt vaginal flora, injure vaginal epithelium, damage the diaphragm or counteract potentially beneficial effects of microbicides are needed. The possibility of removing the diaphragm sooner than the recommended 6 h for contraception should be further studied.
Publication
Journal: Journal of Applied Toxicology
January/3/2007
Abstract
The objective of this study was to assess the level of macrocyclic trichothecenes (MCT), one of the most potent mycotoxins, on wall surfaces, floor dust and air samples from moldy dwellings. The study was based on an index group comprising 15 flooded dwellings contaminated by Stachybotrys chartarum or Chaetomium and a control group comprising nine dwellings without molds on visual inspection and mold sampling. Three samples were collected from each dwelling: a sample from the moldy wall, using a swab, a floor dust sample on a 0.5 m(2) surface with a cloth and an air sample using a pump comprising a 1 microm Teflon filter. The MCT level was measured using a monoclonal, antibody-based ELISA test. Compared with measurements performed in index dwellings, higher MCT values were measured on floor dust samples from moldy dwellings (P = 0.02). Samples from wall surfaces demonstrated nearly significant differences (P = 0.06). No significant differences were observed for air samples (P = 0.15), but some samples showed increased MCT levels. Significant correlations were observed between the levels measured on wall surfaces, floor dust and air samples (P = 0.02 to 0.05). In contrast, no correlation was observed between moldy surface and MCT levels. In conclusion, this paper reports for the first time direct evidence for the presence of MCT in moldy dwellings.
Publication
Journal: Infection Control and Hospital Epidemiology
January/16/2013
Abstract
BACKGROUND
Methicillin-resistant Staphylococcus aureus (MRSA) pulsed-field type (PFT) USA300 causes skin and soft tissue infections in military recruits and invasive disease in hospitals. Chlorhexidine gluconate (CHG) is used to reduce MRSA colonization and infection. The impact of CHG on the molecular epidemiology of MRSA is not known.
OBJECTIVE
To evaluate the impact of 2% CHG-impregnated cloths on the molecular epidemiology of MRSA colonization.
METHODS
Cluster-randomized, double-blind, controlled trial.
METHODS
Marine Officer Candidate School, Quantico, Virginia, in 2007.
METHODS
Military recruits.
METHODS
Thrice-weekly application of CHG-impregnated or control (Comfort Bath; Sage) cloths over the entire body.
METHODS
Baseline and serial (every 2 weeks) nasal and/or axillary swab samples were assessed for MRSA colonization. Molecular analysis was performed with pulsed-field gel electrophoresis.
RESULTS
During training, 77 subjects (4.9%) acquired MRSA, 26 (3.3%) in the CHG group and 51 (6.5%) in the control group (P=.004). When analyzed for PFT, 24 subjects (3.1%) in the control group but only 6 subjects (0.8%) in the CHG group (P=.001) had USA300. Of the 167 colonizing isolates recovered from 77 subjects, 99 were recovered from the control group, including USA300 (40.4%), USA800 (38.4%), USA1000 (12.1%), and USA100 (6.1%), and 68 were recovered from the CHG group, including USA800 (51.5%), USA100 (23.5%), and USA300 (13.2%).
CONCLUSIONS
CHG decreased the transmission of MRSA--more specifically, USA300--among military recruits. In addition, USA300 and USA800 outcompeted other MRSA PFTs at incident colonization. Future studies should evaluate the broad-based use of CHG to decrease transmission of USA300 in hospital settings.
Publication
Journal: Animal Cognition
December/7/2005
Abstract
Male mammals typically outperform their conspecific females on spatial tasks. A sex difference in cues used to solve the task could underlie this performance difference as spatial ability is reliant on appropriate cue use. Although comparative studies of memory in food-storing and non-storing birds have examined species differences in cue preference, few studies have investigated differences in cue use within a species. In this study, we used a one-trial associative food-finding task to test for sex differences in cue use in the great tit, Parus major. Birds were trained to locate a food reward hidden in a well covered by a coloured cloth. To determine whether the colour of the cloth or the location of the well was learned during training, the birds were presented with three wells in the test phase: one in the original location, but covered by a cloth of a novel colour, a second in a new location covered with the original cloth and a third in a new location covered by a differently coloured cloth. Both sexes preferentially visited the well in the training location rather than either alternative. As great tits prefer colour cues over spatial cues in one-trial associative conditioning tasks, cue preference appears to be related to the task type rather than being species dependent.
Publication
Journal: Applied microbiology
April/2/1971
Abstract
The effects of laundering with both anionic and nonionic detergents in cold, warm, and hot water on poliovirus-contaminated cotton sheeting, cotton terry cloth, washable wool shirting, wool blanketing, dull nylon jersey, and dacron/cotton shirting were determined. The fabrics were exposed to virus by aerosolization and direct contact (pipette) in separate studies. Although the results varied with each factor used in the study, virus titers on all the fabrics were generally reduced considerably by the laundering process. When the fabrics were dried for 20 hr after laundering, an additional decline in virus titers was seen, often to below detectable levels. The type of detergent used made little difference in effect on virus titer reduction, but the hot wash water markedly reduced the detectable virus. Fabric type was not a major factor in the majority of the experiments, although virus tended to be eliminated more readily from the nylon jersey, and in warm water the virus persisted longer on wool blanketing material laundered in anionic detergent. Sterile fabrics of each type laundered with similar fabrics which contained virus often became contaminated by the virus during the laundering process. Virus titers ranging from undetectable to 10(3.9) cell culture 50% infectious doses/ml were obtained from samples of the rinse water after warm- and cold-water laundering.
Publication
Journal: Bioresource Technology
January/29/2013
Abstract
This paper presents a comprehensive evaluation of the current status of dynamic membrane (DM) technology as an alternative to membrane bioreactor (MBR) systems. DM filtration makes use of a physical barrier (e.g. cloth or mesh) on which a cake layer is formed. It is already used in traditional filtration systems, but applications in biological wastewater treatment are still at its infancy. Dynamic filtration of sludge has lower risk of fouling and requires less energy and lower capital costs compared to MBR. A review of the state-of-art in both DM materials and configurations is presented. Factors affecting DM performance are discussed in order to determine the optimum and critical approaches for membrane operation. Future perspectives to enhance the applicability and functionality of the technology regarding the treatment and membrane performance are presented.
Publication
Journal: Spatial vision
March/7/1991
Abstract
I present evidence that people assume a simple, linear reflectance function when interpreting shading information. Using this reflectance function I derive a closed-form solution to the problem of extracting shape information from image shading. The solution does not employ an assumption about surface smoothness and so is directly applicable to complex natural surfaces such as hair or cloth. A simple biological mechanism is proposed to implement this recovery of shape. It is shown that this simple mechanism can also extract significant shape information from line drawings.
Authors
Publication
Journal: Mayo Clinic Proceedings
August/8/2000
Abstract
OBJECTIVE
To evaluate the effects of 4 different drying methods to remove bacteria from washed hands.
METHODS
One hundred adult volunteers participated in this randomized prospective study. All bacterial counts were determined using a modified glove-juice sampling procedure. The difference was determined between the amounts of bacteria on hands artificially contaminated with the bacterium Micrococcus luteus before washing with a nonantibacterial soap and after drying by 4 different methods (cloth towels accessed by a rotary dispenser, paper towels from a stack on the hand-washing sink, warm forced air from a mechanical hand-activated dryer, and spontaneous room air evaporation). The results were analyzed using a nonparametric analysis (the Friedman test). By this method, changes in bacterial colony-forming unit values for each drying method were ranked for each subject.
RESULTS
The results for 99 subjects were evaluable. No statistically significant differences were noted in the numbers of colony-forming units for each drying method (P = .72).
CONCLUSIONS
These data demonstrate no statistically significant differences in the efficiency of 4 different hand-drying methods for removing bacteria from washed hands.
Publication
Journal: Infancy
February/19/2017
Abstract
Means-end actions are an early-emerging form of problem-solving. These actions require initiating initial behaviors with a goal in mind. In this study, we explored the origins of 8-monthold infants' means-end action production using a cloth-pulling training paradigm. We examined whether highlighting the goal (toy) or the means (cloth) was more valuable for learning to perform a well-organized means-end action. Infants were given the opportunity to both practice cloth-pulling and view modeling of the action performed by an adult throughout the session. Infants either saw the same toy or the same cloth in successive trials so that the goal or means were highlighted prior to modeling of the action. All infants improved throughout the session regardless of which aspect of the event was highlighted. Beyond this general improvement, repetition of goals supported more rapid learning and more sustained learning than did repetition of means. These findings provide novel evidence that, at the origins of means-end action production, emphasizing the goal that structures an action facilitates the learning of new meansend actions.
Publication
Journal: Journal of the American Mosquito Control Association
July/1/1997
Abstract
Three different resting station designs made of cardboard covered with black cloth were evaluated for their attractiveness to Aedes aegypti populations resting inside houses in Thailand. Box designs attracted more females (but not males) than an open-panel design. Thirty to 60% of all adult Ae. aegypti resting inside houses were collected by aspirating from 2-4 resting boxes placed inside houses. Tall boxes (90 cm) did not attract more females or males than short boxes (45 cm). Forty-two percent more females (but fewer males) were attracted to boxes when oviposition bowls were placed inside the boxes. Four boxes per house attracted 32% more mosquitoes than two boxes. Aspirating from artificial resting stations is an efficient and rapid method for sampling male and teneral, bloodfed, and gravid female Ae. aegypti resting inside houses.
Publication
Journal: IEEE Transactions on Neural Systems and Rehabilitation Engineering
October/27/2009
Abstract
Conductive elastomers are a novel strain sensing technology which can be unobtrusively embedded into a garment's fabric, allowing a new type of sensorized cloths for motion analysis. A possible application for this technology is remote monitoring and control of motor rehabilitation exercises. The present work describes a sensorized shirt for upper limb posture recognition. Supervised learning techniques have been employed to compare classification models for the analysis of strains, simultaneously measured at multiple points of the shirt. The instantaneous position of the limb was classified into a finite set of predefined postures, and the movement was decomposed in an ordered sequence of discrete states. The amount of information given by the observation of each sensor during the execution of a specific exercise was quantitatively estimated by computing the information gain for each sensor, which in turn allows the data-driven optimization of the garment. Real-time feedback on exercise progress can also be provided by reconstructing the sequence of consecutive positions assumed by the limb.
Publication
Journal: Acta chirurgica Scandinavica. Supplementum
July/18/1982
Abstract
Forty-four dogs were used. In experimental animals, Serratia marcescens inoculated cloth were placed on the entrance or exist side before shooting, while in control animals no inoculated cloth was placed. Bullet wounding was carried out to both hind legs from a distance of 20 metres. 5.56 mm calibre bullet was used. The impact velocity was 919 m/s or 716 m/s. Bacteriological examination was made immediately or 6 hrs after the shot. The experimental studies showed that primary bacterial contamination of bullet wounds could be resulted immediately after the shot. And it has been verified that the main mechanisms of primary bacterial contamination were two: (1) The bacteria were sucked into the wound by negative pressure of the temporary cavity at both entrance and exit sides. (2) At entrance side, in addition, bacteria could be further carried into the wound tract by contaminated bullet itself.
Publication
Journal: Anaesthesia and Intensive Care
December/9/2007
Abstract
During the transfer of intubated patients, endotracheal tube security is paramount. This study aims to compare two methods of securing an endotracheal tube in adults: tying with a cloth tape versus the Thomas Endotracheal Tube Holder (Laerdal). A manikin-based study was performed using paramedics and critical care doctors (consultants and senior trainees) as participants. Each participant was asked to secure an endotracheal tube that had been placed within the trachea of a manikin a total of six times, the first three times using tied cloth tape and the last three times using a Thomas Endotracheal Tube Holder. Following each 'fixation' and after the participant had left the room, the security of the tube was tested by applying a fixed force laterally and to the right by dropping a 1.25 kg weight a distance of 50 cm. The amount of movement of the tube with respect to the teeth was measured and recorded in millimetres. Two-hundred-and-seventy tube fixations (135 tied vs. 135 tube holder) were performed by 45 participants. The degree of tube movement was significantly higher when the tube was secured with a tie compared with when the tube holder was used (median movement 22 mm vs. 4 mm, P < 0.0001). We have demonstrated that the tube holder device minimised tube movement in a manikin model when compared with conventional tape tying. The use of this device when transporting intubated patients may reduce the risk of tube displacement though further clinical studies are warranted.
Publication
Journal: Tropical Doctor
September/7/1998
Abstract
In this prospective study, axillary temperature of newborns delivered at home were recorded by a field worker once within a period of 24 h after the birth in 10 villages of Haryana, India, during 1992-1993. Room air temperature was measured at the same time. Family members were interviewed to record newborn care practices. Of the 189 babies, 11.1% were found to be hypothermic (temperature < 35.6 degrees C) and 22.8% were hyperthermic (temperature>> 37.3 degrees C). During winter months 19.1% were hypothermic as compared to only 3.1% in summer whereas 8.5% were hyperthermic in winter compared to 36.8% in summer. Room air temperature of < 24 degrees C was recorded in 41%. A strong correlation was observed between room air temperature and neonatal temperature. At the time of birth, 13.2% of the delivery rooms in summer and 73.6% in winter were reported to have heat source: 58.2% babies were reported to be wiped soon after birth; 97.3% were wrapped in cloth; the head was covered in 59.1% cases in winter and 10.5% in summer; 97.3% babies were kept with mother in same bed but not in skin-to-skin contact; and 65% were bathed within 24 h after delivery. Neonatal hypothermia is a common problem in developing countries. It is important that information, education and communication strategy about appropriate technologies for prevention and management of neonatal hypothermia is provided at domiciliary level. A significant proportion of babies are likely to suffer from hyperthermia in warm countries, specially in summer. Therefore, guidelines for thermal control in home births should be tailored to the specific environmental situation.
Publication
Journal: Angewandte Chemie - International Edition
June/18/2019
Abstract
The modulation of electron density is an effective option for efficient alternative electrocatalysts. Here, p-n junctions are constructed in 3D free-standing FeNi-LDH/CoP/carbon cloth (CC) electrode (LDH=layered double hydroxide). The positively charged FeNi-LDH in the space-charge region can significantly boost oxygen evolution reaction. Therefore, the j at 1.485 V (vs. RHE) of FeNi-LDH/CoP/CC achieves ca. 10-fold and ca. 100-fold increases compared to those of FeNi-LDH/CC and CoP/CC, respectively. Density functional theory calculation reveals OH- has a stronger trend to adsorb on the surface of FeNi-LDH side in the p-n junction compared to individual FeNi-LDH further verifying the synergistic effect in the p-n junction. Additionally, it represents excellent activity toward water splitting. The utilization of heterojunctions would open up an entirely new possibility to purposefully regulate the electronic structure of active sites and promote their catalytic activities.
Publication
Journal: Archives of Environmental Contamination and Toxicology
September/8/1993
Abstract
A factory survey was conducted in the second half of a working week on 41 exposed male workers, who were engaged in fiber-reinforced plastics work and exposed to the mixed vapors of styrene and acetone. Nonexposed workers, 20 men, were recruited from the same factory. Styrene and acetone in respiratory zone air were monitored for a 8-h shift with carbon cloth- and water-equipped personal diffusive samplers, respectively. Blood and urine samples were collected at the shift-end. Acetone and styrene concentrations in whole blood, serum and urine were measured by head-space gas chromatography, and phenylglyoxylic acid in urine by high-performance liquid chromatography. All biological exposure indicators analyzed correlated significantly with the intensity of exposure to the corresponding solvent during the shift. The slopes of the regression lines indicate that a very small fraction of styrene absorbed will be excreted into urine as styrene per se, and that styrene is quite effectively excreted into urine after metabolic conversion. In contrast, the slopes of regression lines for acetone suggest that acetone distributes both in the blood and urine quite evenly. When the distribution of the solvent in serum was compared with that in the whole blood, it was found that almost all of styrene in blood is present in the serum, whereas acetone distributed very evenly in the cellular and noncellular fractions of the blood.
Publication
Journal: Journal of Thoracic and Cardiovascular Surgery
October/1/1987
Abstract
A number of centers have recorded a significant incidence of primary tissue failure with the standard Ionescu-Shiley pericardial valve. In most cases severe regurgitation was caused by leaflet tears adjacent to the edge of the cloth-covered stent. Our early clinical experience (up to 4 years' follow-up) with two new pericardial valves (Ionescu-Shiley low-profile and Hancock pericardial valves) has shown that primary tissue failure also occurs in these new valves. In vitro accelerated fatigue studies on seven of these valves (size 29 mm) showed that in vitro premature leaflet failure was caused by abrasion of the leaflet on the cloth-covering at the edge of the stent. Clinically, endothelialization and host tissue ingrowth on the cloth and the leaflets at the edge of the frame greatly reduced the amount of abrasion and the incidence of tissue failure. In seven of the eight explanted valves studied, leaflet tears occurred at the top of the stent posts where there was less endothelialization and tissue ingrowth, close to the points where sutures pass through the leaflets. It is likely that both abrasion and stress concentration around these sutures contributed to the tissue failures in the clinical valves.
Publication
Journal: Indoor Air
April/15/2009
Abstract
The aims of this study were first to assess airborne endotoxin levels in the dwellings of 162 newborns living in Paris twice during a 1-year period, and second, to identify predictors for endotoxin concentrations using questionnaire data in relation to housing factors and living conditions. Air samples were collected on a glass fiber filter in polystyrene filter holders, using a pump at a flow rate of 3.5 l/min for 24 h placed in the main room of the home. Endotoxin levels were measured using a chromogenic kinetic Limulus Amoebocyte Lysate test. Geometric means (geometric standard deviation) of airborne endotoxin levels at two different visits were respectively 0.509 (4.289) EU/m3 and 0.557 (3.029) EU/m3. Airborne endotoxin levels were significantly increased: (i) in cold season (P = 0.024), with (ii) the presence of visible cockroaches in the previous 12 months at home (P < 0.001), (iii) increased number of inhabitants per square meter (P = 0.012), (iv) the high frequency of cleaning with the floor cloths (P = 0.0014), and (v) the low frequency of vacuuming (P = 0.0045). This study provided for the first time airborne endotoxin levels issued from repeated measurements in Paris dwellings. PRACTICAL IMPLICATIONS This analysis contributed to identify a few factors that determined indoor airborne endotoxin levels. However, the predictive model including housing factors and living conditions poorly estimated endotoxin levels. Consequently, multiple samples and longer sampling periods might improve the estimate of long-term airborne endotoxin exposure especially its variability, in cohort studies.
load more...