Electron tomography of ice-embedded prokaryotic cells.
Journal: 1998/May - Biophysical Journal
ISSN: 0006-3495
Abstract:
Whole cells of archaea were embedded in vitreous ice by plunge freezing and investigated by automated energy-filtered electron tomography at 120 kV. The embedded cells were between 300 and 750 nm thick, and their structures were reconstructed to a resolution of 20-40 nm from tilt series comprising 50-140 images. The dose was kept within tolerable limits. A resolution of 20 nm allowed visualization of the individual stalks of the S-layer of Pyrobaculum aerophilum cells, which had undergone partial lysis, in three dimensions. The attainable resolution for low-dose electron tomography under different experimental conditions was theoretically investigated in terms of the specimen thickness. To obtain 2-nm resolution at 120 kV (300 kV), the specimen must not be thicker than 100 nm (150 nm). For a resolution of 10 nm, the maximum thickness is 450 nm (700 nm). An accelerating voltage of 300 kV is advantageous, mainly for specimens thicker than 100 nm. Experimental investigations so far have resulted in a resolution that is worse by a factor of 2-5 as compared to theory.
Relations:
Content
Citations
(35)
References
(26)
Chemicals
(1)
Organisms
(2)
Processes
(1)
Similar articles
Articles by the same authors
Discussion board
Biophys J 74(2 Pt 1): 1031-1042

Electron tomography of ice-embedded prokaryotic cells.

Abstract

Whole cells of archaea were embedded in vitreous ice by plunge freezing and investigated by automated energy-filtered electron tomography at 120 kV. The embedded cells were between 300 and 750 nm thick, and their structures were reconstructed to a resolution of 20-40 nm from tilt series comprising 50-140 images. The dose was kept within tolerable limits. A resolution of 20 nm allowed visualization of the individual stalks of the S-layer of Pyrobaculum aerophilum cells, which had undergone partial lysis, in three dimensions. The attainable resolution for low-dose electron tomography under different experimental conditions was theoretically investigated in terms of the specimen thickness. To obtain 2-nm resolution at 120 kV (300 kV), the specimen must not be thicker than 100 nm (150 nm). For a resolution of 10 nm, the maximum thickness is 450 nm (700 nm). An accelerating voltage of 300 kV is advantageous, mainly for specimens thicker than 100 nm. Experimental investigations so far have resulted in a resolution that is worse by a factor of 2-5 as compared to theory.

Full Text

The Full Text of this article is available as a PDF (1.0M).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Barnard DP, Turner JN, Frank J, McEwen BF. A 360 degrees single-axis tilt stage for the high-voltage electron microscope. J Microsc. 1992 Jul;167(Pt 1):39–48. [PubMed] [Google Scholar]
  • Baumeister W, Wildhaber I, Phipps BM. Principles of organization in eubacterial and archaebacterial surface proteins. Can J Microbiol. 1989 Jan;35(1):215–227. [PubMed] [Google Scholar]
  • Braunfeld MB, Koster AJ, Sedat JW, Agard DA. Cryo automated electron tomography: towards high-resolution reconstructions of plastic-embedded structures. J Microsc. 1994 May;174(Pt 2):75–84. [PubMed] [Google Scholar]
  • Brock TD, Brock KM, Belly RT, Weiss RL. Sulfolobus: a new genus of sulfur-oxidizing bacteria living at low pH and high temperature. Arch Mikrobiol. 1972;84(1):54–68. [PubMed] [Google Scholar]
  • Dierksen K, Typke D, Hegerl R, Walz J, Sackmann E, Baumeister W. Three-dimensional structure of lipid vesicles embedded in vitreous ice and investigated by automated electron tomography. Biophys J. 1995 Apr;68(4):1416–1422.[PMC free article] [PubMed] [Google Scholar]
  • Dubochet J, Adrian M, Chang JJ, Homo JC, Lepault J, McDowall AW, Schultz P. Cryo-electron microscopy of vitrified specimens. Q Rev Biophys. 1988 May;21(2):129–228. [PubMed] [Google Scholar]
  • Grimm R, Bärmann M, Häckl W, Typke D, Sackmann E, Baumeister W. Energy filtered electron tomography of ice-embedded actin and vesicles. Biophys J. 1997 Jan;72(1):482–489.[PMC free article] [PubMed] [Google Scholar]
  • Grimm R, Typke D, Bärmann M, Baumeister W. Determination of the inelastic mean free path in ice by examination of tilted vesicles and automated most probable loss imaging. Ultramicroscopy. 1996 Jul;63(3-4):169–179. [PubMed] [Google Scholar]
  • Han KF, Gubbens AJ, Sedat JW, Agard DA. Optimal strategies for imaging thick biological specimens: exit wavefront reconstruction and energy-filtered imaging. J Microsc. 1996 Aug;183(Pt 2):124–132. [PubMed] [Google Scholar]
  • Hegerl R. The EM Program Package: A Platform for Image Processing in Biological Electron Microscopy. J Struct Biol. 1996 Oct;116(1):30–34. [PubMed] [Google Scholar]
  • Hell SW, Schrader M, van der Voort HT. Far-field fluorescence microscopy with three-dimensional resolution in the 100-nm range. J Microsc. 1997 Jul;187(Pt 1):1–7. [PubMed] [Google Scholar]
  • Kirz J, Jacobsen C, Howells M. Soft X-ray microscopes and their biological applications. Q Rev Biophys. 1995 Feb;28(1):33–130. [PubMed] [Google Scholar]
  • Koster AJ, Chen H, Sedat JW, Agard DA. Automated microscopy for electron tomography. Ultramicroscopy. 1992 Oct;46(1-4):207–227. [PubMed] [Google Scholar]
  • Krivanek OL, Friedman SL, Gubbens AJ, Kraus B. An imaging filter for biological applications. Ultramicroscopy. 1995 Jul;59(1-4):267–282. [PubMed] [Google Scholar]
  • Langmore JP, Smith MF. Quantitative energy-filtered electron microscopy of biological molecules in ice. Ultramicroscopy. 1992 Oct;46(1-4):349–373. [PubMed] [Google Scholar]
  • Mannella CA, Marko M, Penczek P, Barnard D, Frank J. The internal compartmentation of rat-liver mitochondria: tomographic study using the high-voltage transmission electron microscope. Microsc Res Tech. 1994 Mar 1;27(4):278–283. [PubMed] [Google Scholar]
  • McEwen BF, Downing KH, Glaeser RM. The relevance of dose-fractionation in tomography of radiation-sensitive specimens. Ultramicroscopy. 1995 Oct;60(3):357–373. [PubMed] [Google Scholar]
  • Moritz M, Braunfeld MB, Sedat JW, Alberts B, Agard DA. Microtubule nucleation by gamma-tubulin-containing rings in the centrosome. Nature. 1995 Dec 7;378(6557):638–640. [PubMed] [Google Scholar]
  • Olins AL, Olins DE, Levy HA, Margle SM, Tinnel EP, Durfee RC. Tomographic reconstruction from energy-filtered images of thick biological sections. J Microsc. 1989 Jun;154(Pt 3):257–265. [PubMed] [Google Scholar]
  • Perkins G, Renken C, Martone ME, Young SJ, Ellisman M, Frey T. Electron tomography of neuronal mitochondria: three-dimensional structure and organization of cristae and membrane contacts. J Struct Biol. 1997 Aug;119(3):260–272. [PubMed] [Google Scholar]
  • Phipps BM, Huber R, Baumeister W. The cell envelope of the hyperthermophilic archaebacterium Pyrobaculum organotrphum consists of two regularly arrayed protein layers: three-dimensional structure of the outer layer. Mol Microbiol. 1991 Feb;5(2):253–265. [PubMed] [Google Scholar]
  • Saxton WO, Baumeister W, Hahn M. Three-dimensional reconstruction of imperfect two-dimensional crystals. Ultramicroscopy. 1984;13(1-2):57–70. [PubMed] [Google Scholar]
  • Sayre D, Chapman HN. X-ray microscopy. Acta Crystallogr A. 1995 May 1;51(Pt 3):237–252. [PubMed] [Google Scholar]
  • Schleper C, Holz I, Janekovic D, Murphy J, Zillig W. A multicopy plasmid of the extremely thermophilic archaeon Sulfolobus effects its transfer to recipients by mating. J Bacteriol. 1995 Aug;177(15):4417–4426.[PMC free article] [PubMed] [Google Scholar]
  • Völkl P, Huber R, Drobner E, Rachel R, Burggraf S, Trincone A, Stetter KO. Pyrobaculum aerophilum sp. nov., a novel nitrate-reducing hyperthermophilic archaeum. Appl Environ Microbiol. 1993 Sep;59(9):2918–2926.[PMC free article] [PubMed] [Google Scholar]
  • Zimmerman SB, Trach SO. Estimation of macromolecule concentrations and excluded volume effects for the cytoplasm of Escherichia coli. J Mol Biol. 1991 Dec 5;222(3):599–620. [PubMed] [Google Scholar]
Max-Planck-Institut für Biochemie, Martinsried, Germany.
Max-Planck-Institut für Biochemie, Martinsried, Germany.

Abstract

Whole cells of archaea were embedded in vitreous ice by plunge freezing and investigated by automated energy-filtered electron tomography at 120 kV. The embedded cells were between 300 and 750 nm thick, and their structures were reconstructed to a resolution of 20-40 nm from tilt series comprising 50-140 images. The dose was kept within tolerable limits. A resolution of 20 nm allowed visualization of the individual stalks of the S-layer of Pyrobaculum aerophilum cells, which had undergone partial lysis, in three dimensions. The attainable resolution for low-dose electron tomography under different experimental conditions was theoretically investigated in terms of the specimen thickness. To obtain 2-nm resolution at 120 kV (300 kV), the specimen must not be thicker than 100 nm (150 nm). For a resolution of 10 nm, the maximum thickness is 450 nm (700 nm). An accelerating voltage of 300 kV is advantageous, mainly for specimens thicker than 100 nm. Experimental investigations so far have resulted in a resolution that is worse by a factor of 2-5 as compared to theory.

Abstract
Full Text
Selected References
Collaboration tool especially designed for Life Science professionals.Drag-and-drop any entity to your messages.