Back to product search
$345.00
48T
48T -$345.00
96T -$650.00
96T*5 -$2,925.00
96T*50 -$26,000.00
RIDACOM Ltd. hotline:
Mouse Angiotension I (ANG-1) ELISA Kit
Description:
Angiotensin I is formed by the action of renin on angiotensinogen. Renin cleaves the peptide bond between the leucine (Leu) and valine (Val) residues on angiotensinogen, creating the ten-amino acid peptide (des-Asp) angiotensin I. Renin is produced in the kidneys in response to renal sympathetic activity, decreased intrarenal blood pressure (<90mmHg systolic blood pressure ) at the juxtaglomerular cells, or decreased delivery of Na+ and Cl- to the macula densa. If a reduced NaCl concentration in the distal tubule is sensed by the macula densa, renin release by juxtaglomerular cells is increased. This sensing mechanism for macula densa-mediated renin secretion appears to have a specific dependency on chloride ions rather than sodium ions. Studies using isolated preparations of thick ascending limb with glomerulus attached in low NaCl perfusate were unable to inhibit renin secretion when various sodium salts were added but could inhibit renin secretion with the addition of chloride salts.
Test method:Colorimetric
Precautions:
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Alternative:
ANG-1
Storage conditions:The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.
Delivery conditions:Gel pack with blue ice.
Usage:
• Do not mix components from different kit lots or use reagents beyond the kit expiration date.
• Allow all reagents to warm to room temperature for at least 30 minutes before opening.
• Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
• Unused wells must be kept desiccated at 4 °C in the sealed bag provided.
• Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
• It is recommended that all samples and standards be assayed in duplicate or triplicate.
Sensitivity:64.46 pg/mL
Sample type:
Cell culture supernatants
Serum
Plasma
Other biological fluids
Assay length:Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components:
• Mouse Angiotension I microplate
• Mouse Angiotension I standard
• Mouse Angiotension I detect antibody
• Streptavidin-HRP
• Standard diluent
• Assay buffer
• HRP substrate
• Stop solution
• Wash buffer
• Plate covers
Calibration range:75 - 4800pg/mL