Back to product search
$706.00
48T
48T -$706.00
96T -$1,008.00
96T*5 -$4,536.00
96T*10 -$8,568.00
96T*100 -$70,560.00
RIDACOM Ltd. hotline:
CLIA Kit for Connective Tissue Growth Factor (CTGF)
Antigen:
CCN2
Synonyms: The microplate provided in this kit has been pre-coated with an antibody specific to Connective Tissue Growth Factor (CTGF). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Connective Tissue Growth Factor (CTGF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Connective Tissue Growth Factor (CTGF) level in the sample or standard.
Reactivity:Wild boar
Application:Chemiluminescent immunoassay for Antigen Detection
Shelf life:NOV2
Storage conditions:Insulin-Like Growth Factor-Binding Protein 8
Delivery conditions:Hypertrophic Chondrocyte-Specific Protein 24
Usage:
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
Sensitivity:Porcine (Pig)
Sample type:
The minimum detectable dose of this kit is typically less than 0.13ng/mL
Specificity:
Double-antibody Sandwich
Precision:
This assay has high sensitivity and excellent specificity for detection of Connective Tissue Growth Factor (CTGF).
No significant cross-reactivity or interference between Connective Tissue Growth Factor (CTGF) and analogues was observed.
Stability:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Connective Tissue Growth Factor (CTGF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Connective Tissue Growth Factor (CTGF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Procedure:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Current View