Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.
Journal: 2001/October - Hypertension
ISSN: 1524-4563
PUBMED: 11641312
Abstract:
Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer function to synthesize the ascending aortic pressure pulse from the radial pulse. Validity of this approach was tested for estimation of aortic systolic, diastolic, pulse, and mean pressures from the radial pressure waveform. Ascending aortic and radial pressure waveforms were recorded simultaneously at cardiac surgery, before initiation of cardiopulmonary bypass, with matched, fluid-filled manometer systems in 62 patients under control conditions and during nitroglycerin infusion. Aortic pressure pulse waves, generated from the radial pulse, showed agreement with the measured aortic pulse waves with respect to systolic, diastolic, pulse, and mean pressures, with mean differences <1 mm Hg. Control differences in Bland-Altman plots for mean+/-SD in mm Hg were systolic, 0.0+/-4.4; diastolic, 0.6+/-1.7; pulse, -0.7+/-4.2; and mean pressure, -0.5+/-2.0. For nitroglycerin infusion, differences respectively were systolic, -0.2+/-4.3; diastolic, 0.6+/-1.7; pulse, -0.8+/-4.1; and mean pressure, -0.4+/-1.8. Differences were within specified limits of the Association for the Advancement of Medical Instrumentation SP10 criteria. In contrast, differences between recorded radial and aortic systolic and pulse pressures were well outside the criteria (respectively, 15.7+/-8.4 and 16.3+/-8.5 for control and 14.5+/-7.3 and 15.1+/-7.3 mm Hg for nitroglycerin). Use of a generalized transfer function to synthesize radial artery pressure waveforms can provide substantially equivalent values of aortic systolic, pulse, mean, and diastolic pressures.
Relations:
Citations
(200)
Diseases
(1)
Drugs
(2)
Organisms
(1)
Processes
(1)
Anatomy
(2)
Affiliates
(2)
Similar articles
Articles by the same authors
Discussion board
Collaboration tool especially designed for Life Science professionals.Drag-and-drop any entity to your messages.